Surgeon Q&A: Can an Aortic Valve Replacement Fit in the Mitral Position?

By Adam Pick on October 17, 2016

I just received a great question from Dorothy about heart valve replacements. Dorothy asked me, "Hi Adam, Why can some of the newer valves, like the Perceval and Trifecta GT, only be used in the aortic position and not the mitral? If those valves are new and good shouldn't they be used in the mitral position as well? I have moderate mitral stenosis. Thanks Adam!"

aortic-mitral-replacement-farivar

To help Dorothy, I contacted Dr. Robert Saeid Farivar. So you know, Dr. Farivar is a has performed successful surgery on many patients in our community including Tammi Gunwall, Julie Mcdonald-Lindgren and Rob Johnston.

Dr. Robert Saeid Farivar

Dr. Robert Saeid Farivar

In his response, Dr. Farivar shared three important reasons why mitral valve replacements are not used in the aortic valve position:

That is a great question Dorothy. In theory, an aortic valve could be used in the mitral valve position by turning them upside down. In practicality, we don't do that for a couple of reasons:
  • First, mitral valve openings are larger than aortic valve openings. So, the aortic valve is not wide enough.

  • Second, the profile height of the valve is very important in the mitral position. We like to have a "low profile" mitral valve so that it does not obstruct the left ventricular outflow tract.

  • Third, a valve like the Perceval is specifically designed to only sit in the aortic position since it is so "tall".

Perceval

Perceval Sutureless Heart Valve

Then, Dr. Farivar addressed the impact of pressure on aortic valve performance and durability in the mitral valve position:

Another important fact for patients to knowโ€ฆ The mitral and aortic valves have different pressure cycling. The aortic valve, for example, cycles between systolic and diastolic pressure (let's say 120 mm Hg and 80 mm Hg, thus a 40 mm Hg difference). The mitral valve cycles between systolic and diastolic pressure at essentially 0. That said, there is a higher cycling pressure in the aortic valve and therefore a greater tendency for the valve to "wear out".

Lastly, Dr. Farivar addresses a special congenital case in which aortic valves have been used in the mitral valve position:

In congenital cases, where we need a really small mitral valve, we have turned aortic mechanical valves upside down... but that is the only case.

Many thanks to Dorothy for her awesome question. Also, I would like to extend a special thanks to Dr. Farivar for sharing his clinical experience and research with our community!!!

Keep on tickin!
Adam

Written by Adam Pick - Patient & Website Founder

Written by Adam Pick - Patient & Website Founder

Adam Pick is a heart valve patient and author of The Patient's Guide To Heart Valve Surgery. In 2006, Adam founded HeartValveSurgery.com to educate and empower patients. This award-winning website has helped over 10 million people fight heart valve disease. Adam has been featured by the American Heart Association and Medical News Today.

Follow 450K

Comments

Leave a Comment

Your message...
Submit

New Posts From Our Community

Pat Williams - Heart Valve Patient

Pat Williams from
Raleigh

test

Meet Pat
Hunter Testing - Heart Valve Patient

Hunter Testing from
Los Angeles

more testing images

Meet Hunter
Maria Santos - Heart Valve Patient

Maria Santos from
Austin, Texas

Test

Meet Maria

Newest Community Post

Pat Williams - Heart Valve Patient

Pat Williams from
Raleigh

test

Meet Pat
Find Heart Valve Surgeons

Find Heart Valve Surgeons

Search 1,500 patient-recommended surgeons

Heart Hospital Map

Heart Hospital Map

Search for heart hospitals that specialize in heart valve treatment.

Surgeon Finder

Surgeon Finder

Find and research over 1,500 patient-recommended heart valve surgeons.